Skip links

Circadian lighting design specification for offices

Detail Lighting designs and supplies architectural lighting for commercial interiors across the UK, working alongside architects, lighting designers and specifiers. Circadian lighting design has moved from a research topic into a practical specification decision for offices, and it changes how luminaires are selected, controlled and coordinated.

Here, we discuss the principles behind circadian lighting for offices, the design considerations that matter at specification stage, and how to build a scheme that supports occupant wellbeing without compromising visual performance or energy compliance.

Manchester Square Marylebone Office Space

What circadian lighting means in an office context

The circadian rhythm is the body’s roughly 24-hour internal clock. It is set primarily by light reaching specialised cells in the eye, the intrinsically photosensitive retinal ganglion cells, which contain the pigment melanopsin.

These cells are most sensitive to short-wavelength, blue-rich light at around 480 nanometres. The intensity and spectrum of light entering the eye through the day signals to the body when to be alert and when to wind down.

Conventional office lighting is designed for visual tasks. EN 12464-1 sets a maintained illuminance of 500 lux on the working plane for general office work, but a horizontal lux figure says nothing about the spectral quality or the vertical light reaching the occupant’s eye.

Circadian lighting design adds that missing dimension. It tunes both intensity and colour temperature across the working day, typically cooler and brighter through the morning, then warmer and lower in the late afternoon.

The intent is to reinforce daytime alertness in occupants who spend most daylight hours indoors, while avoiding light that suppresses evening melatonin production. In an office, that means the lighting scheme actively supports the people using the space, not just the tasks they perform.

Office lighting

The metrics that matter at specification stage

Horizontal task illuminance remains necessary, but it is not sufficient for circadian design. Two additional measures do the work.

  • Melanopic equivalent daylight illuminance (mEDI). Measured on the vertical plane at eye level and defined in CIE S 026, this quantifies the light that actually drives the circadian response. It is the metric used by the WELL Building Standard v2 in its circadian lighting feature, which sets target mEDI values at workstations during specified daytime hours.
  • Circadian stimulus (CS). An alternative model developed by the Lighting Research Center, expressing the effectiveness of a light source at stimulating the circadian system on a 0 to 0.7 scale.

Correlated colour temperature (CCT) is the design lever most specifiers recognise. A tunable white scheme shifting from around 5000 to 6500 Kelvin in the morning down towards 2700 to 3000 Kelvin later in the day changes both the appearance and the melanopic content of the light. The measurement that governs circadian effect is vertical illuminance at the eye, not the reading taken on the desk.

Design considerations for an office scheme

Tunable white luminaires and control

Circadian schemes depend on tunable white luminaires driven by an addressable control protocol, most commonly DALI Device Type 8 (DT8), which handles colour temperature change within a single control channel. The control layer is as important as the fittings.

Automated time schedules, daylight linking and pre-set scenes deliver the daily shift without relying on occupants to adjust it manually. Detail Lighting’s commercial lighting solutions include tunable white and controllable ranges suited to office specification, alongside the controls to run them.

Layering the scheme

A circadian office is built in layers rather than a single grid of downlights. Each layer contributes to horizontal task levels, vertical eye-level light, or visual interest, and the mix determines how effectively the scheme raises melanopic light without glare.

  • Recessed downlights such as the Archinto Adjustable give controlled general and task lighting, with adjustability to direct light onto vertical surfaces where needed.
  • Track lighting such as the ALT45 48v spotlight, or the Cortes 48v deep surface and suspended track, adds flexibility to reposition and re-aim fittings as layouts change, which matters in offices that are reconfigured over time.
  • Linear LED such as the Volans Premium COB IP20 provides even, low-glare illumination and can wash walls and ceilings to lift vertical light levels.
  • Surface and pendant fittings such as the SD041-15w suit spaces with limited ceiling void or where a suspended element brings light closer to the working plane.

Raising melanopic light at the eye is most effective through bright, well-lit vertical surfaces. Walls, partitions and ceilings that carry light contribute more to the circadian signal than a fitting aimed straight down at a desk.

Glare, uniformity and visual comfort

Higher daytime intensities must not come at the expense of comfort. EN 12464-1 sets a unified glare rating of UGR 19 or below for most office tasks, and this constraint holds regardless of the circadian brief.

Achieving brighter mornings without discomfort relies on good optics, adequate shielding and, where appropriate, an indirect component that lights the ceiling. Screen-based work makes glare control and luminance balance non-negotiable.

Daylight integration

Daylight is the strongest and most complete circadian signal available. Electric lighting should supplement it, not attempt to replace it. Perimeter zones close to glazing need daylight-linked dimming so the electric contribution steps back when daylight is sufficient, while deeper floorplates carry more of the circadian load through the tunable white scheme.

Coordinating luminaire zoning with the daylight available across the floorplate is central to a scheme that performs and remains efficient.

Manchester Square Marylebone Office Lighting

Coordination and compliance

Circadian schemes tend to run at higher daytime levels and add control infrastructure, both of which have energy implications. Part L of the Building Regulations governs the energy efficiency of the lighting installation, so high-efficacy LED luminaires and effective controls are needed to reconcile brighter, tunable lighting with compliance.

Efficient sources and automated controls that dim and switch appropriately are what keep a circadian scheme within energy budget.

EN 12464-1:2021 formally introduced provisions relating to lighting for wellbeing, including the option to specify higher illuminance and attention to the light in the wider room, not only the task area.

Coordination with the M&E design is essential, covering ceiling voids, control wiring, driver locations and the low-voltage track infrastructure that several fittings use. Commissioning also needs planning. Scenes and schedules must be set, documented and handed over, with a sensible level of occupant override retained.

When circadian lighting is worth specifying

Circadian lighting is not equally justified on every project. The benefit is greatest where occupants spend long hours indoors with limited access to daylight, in deep-plan floorplates, or where working patterns extend beyond standard daytime hours.

In a naturally well-daylit office used only during the day, daylight already provides much of the circadian signal and the case for a full tunable white scheme is weaker.

The trade-offs are real. Tunable white luminaires and DALI controls cost more than fixed-output equivalents, the control system needs commissioning and ongoing maintenance, and the supporting evidence base is still developing.

A proportionate approach often prioritises circadian provision in focus zones, break-out areas and spaces with poor daylight, rather than applying it uniformly across every area.

Specifying circadian office lighting with Detail Lighting

Detail Lighting works with architects, interior designers and lighting designers to specify circadian and tunable white schemes for offices, from product selection and controls strategy through to samples and technical support. The commercial lighting range covers the downlights, track, linear and surface fittings a layered circadian scheme needs, with the control options to run them across the working day. To develop a scheme for a specific project, get in touch with the Detail Lighting team for a lighting design consultation.

If you require lighting schemes for your project
get in touch with our team

Are you looking for sustainable lighting solutions for your project?
Call us
+44 (0)1908 613256
Email us
sales@detaillighting.co.uk